Configuration SMS messages
Below you can find list of possible SMS configuration commands for 2N® Lift8. In list below, you can see exact format of available messages. You can use up to 5x160 characters per SMS message as 2N® Lift8 supports long SMS messages.
- Configuration:
L8 CNF 12345 011=00420222222222 012=00420111111111 (You can use any available parameter from parameter chart) - Put 2N® Lift8 into the factory default:
L8 DEF 12345 - Restart:
L8 RST 12345
Possible responses
Confirmation messages
L8 CNF OK - configuration was applied
L8 DEF OK - reset to factory default was successful
L8 SET OK - switch of profile was successful
L8 RST OK - restart of the device was successful
Error messages
L8 ERR Invalid Message -If L8 sign is missing or is different (L2, L4 WHATEVER ELSE)
L8 ERR Unknown Command -If another command then CNF, DEF, SET a RST was applied (DFE FNC ETC ...)
L8 ERR Invalid Password - Incorrect password for programming (default is 12345)
L8 ERR Invalid Parameters - releated to CNF and SET.
L8 ERR Invalid Syntax -Syntax error, when there are some spaces or chars where shouldn’t be
L8 ERR Does not Respond - doesn’t answer the call after 60 sec
- when the call is answered but doesn’t react for CPC programming
- hang up during programming
- doesnt react on WRITE_START, WRITE_CONFIRM, or CRC_REQUEST